Hyundai Molded Case Circuit Breaker.


Optimum design provides easy-to-use customer installation, while offering versatility and high performance to match today's demand for a reliable and cost effective product, which is easy to maintain.


Features

    High Breaking Capacity

    Standardization

    • Since MCCBs have the same size for main part so that manufacturing cost can be reduced through standardizing design and panel building process.

Cassette Type Accessories

  • Cassette type accessories can be installed by one-touch method without screws.
  • Auxiliary switch and alarm switch can be installed into a 3P or 4P MCCB with shunt trip or under voltage trip at the same time. (Max. Three accessories can be installed into a MCCB at the same time).

Adjustable Rated Current & Adjustable Instantaneous Current

  • This function will be applied up to 250AF.

Standard & Certification

    Applied Standard

    • KSC 8321
    • IEC 60947
    • NEMA AB-1
    • VDE 0660
    • JIS C8370
    • EN 60947-1 & 60947-2

      Approval & Certification

    • ISO 9001/14000(International Standard Organization)
    • CESI : Centro Electrocnio Sepermentale Italiano
    • KERI : Korea Electrotechnology Research Institude
    • LR : Lloyd's Register of Shipping
    • AB : American Bureau of Shipping
    • BV : Bureau Veritas
    • KR : Korean Register of Shipping
    • GL : Germanischer Lloyd
    • NK : Nippon Kaiji Kyokai
    • KS : Korea Industrial Standard
    • Nuclear Performance Test(1E Class)
    • CE : Community European : TÜV Rheinlend

    Accessories

      Internal Accessories

      Auxiliary Switch (AUX)

      • Makes electrical signals for the breaker status, ON or OFF.

      Alarm Switch (ALT)

      • Indicates electrically the tripped status of breaker.

      Shunt Trip (SHT)

      • Trips the breaker electrically.

      Under Voltage Trip (UVT)

      • Trips the breaker automatically at under set value for the circuit voltage.

    External Accessories

    Operating Mechanism (TFG/TFH)

    • For external hand-operation of MCCB inside a switchgear.
    • TFG : Installed on MCCB.
    • TFH : Connected to MCCB through rod.

    Extended Handle (TFA)

    • Reduces operation efforts for ON, OFF, and RESET.

    Terminal Cover (TCF)

    • Protects the line and load terminals of MCCB.

    Interpole Barriers (TQQ)

    • Isolates terminals to prevent short-circuiting between two or more terminals.