Soft Starters, DC Injection Brackes, Digital Motor Relays, Supervsion Control
Soft Starters Dc Injection Brakes Digital Motor Relays Supervision & Control
About Us
Products
Applications
Downloads
Contact Us
Press Office
Solcon
HRVS-DN Medium Voltage, Digital Soft Starter

1500-13,800V, 60-1000A

The HRVS-DN is a third generation, Medium Voltage, digital soft starter, designed for use with standard asynchronous and synchronous motors. This highly sophisticated soft starter ensures smooth, step-less acceleration and deceleration, eliminating current and mechanical shocks on motor and load.

The HRVS-DN may be supplied as chassis type or a complete system including Line and/or Bypass Contactors. Addible options are Load Break Switch, Fuses, Motor Protection Relay, etc

Advantages at a Glance

    • Innovative low voltage test mode - full testing with a small L.V motor using standard built in features
    • Advanced Electronic Potential Transformer utilizing Patent Pending "wireless" fiber-optic firing system
    • Each starter is tested for Partial Discharge (Korona) ensuring long term reliability
    • Power factor capacitors can be connected directly to the upstream contactor
    • Heavy duty design at 50°C ambient temperature
    • Reduced inrush current and mechanical shock
    • Third generation microprocessor circuitry
    • Soft, stepless acceleration & deceleration
    • Unique starting & stopping characteristics
    • Sophisticated motor protection package
    • User friendly, easy setting and operation
    • IP30-standard, higher protection by special order
    • Two optional methods of delivery: Chassis type for self assembly or Complete system
    • RS485 Communication with MODBUS, PROFIBUS or MODBUS/TCP protocols (others - upon request)
    • Wide 45-65Hz Auto-tracking frequency range combining special software with unique hardware arrangement
      (designed for Marine, Offshore and Generators operating under continuous frequency variation)
    • Torque and current starting and stopping characteristics.
    • Pump control software.

Starting & Stopping

    • Soft start and soft stop
    • Current limit
    • Torque & Current Control ramps
    • Pump Control characteristics
    • Pulse (kick) start
    • Tacho/encoder feedback (option)
    • Dual Adjust - 2 start/stop characteristics for varying loads, two speed motors, etc.
    • Soft starting, Soft Stopping and Final Torque of an HRVS-DN utilizing our infamous "Pump Control Program"

Setting & Supervision

    • Illuminated LCD with 2 lines, 16 characters each
    • Selectable languages: English, German, French or Spanish
    • The LCD displays motor current, fault description and statistical data
    • Easy setting using six soft-touch keys with default parameters
    • Eight LEDs for a quick status display:
    • Control voltage On-Self Test OK
    • Motor soft starting
    • Motor running
    • Motor soft stopping
    • Motor stopped
    • Test Mode Activated
    • Dual Adjust mode
    • Fault

Statistics

    • Last Starting Period
    • Last Start Maximum Current
    • Total Run Time
    • Number of Starts
    • Last Trip
    • Trip Current
    • Total Number of Trips
    • Historical Trip Event Recorder (10 Event conditions)

Control Inputs & Outputs

    • Control voltage: 110-120, 220-240VAC / 50-60Hz or 110 - 220VDC to be specified
    • Separate inputs for Start, Stop (Emergency) and Soft Stop
    • Two programmable External fault inputs - will stop the motor 2 sec. After the contact closes
    • Aux. Contacts - three C/O relays, 8A, 250V, 2000VA:
    • Immediate Relay - changes position upon start signal, with adjustable On & Off delays.
    • Returns to original position upon Voltage Outage, Fault, Stop signal and Soft stop signal
      at the end of soft stopping process. It can also be configured as a "Shear-pin Alarm" contact.
    • End of Acceleration Relay - operates upon completion of starting process, with adjustable
      On delay. Returns to original position upon Voltage outage, Fault, Stop and Soft Stop signals.
    • Fault Relay - can be programmed as:
    • Fault - changes position upon Fault, returns to original position upon Reset.
    • Fault-Fail-Safe - changes position upon control voltage connection, returns upon fault.

Typical Applications

    • Fans and centrifuges
    • Conveyors and monorail systems
    • Pumps, Compressors and Chillers
    • Starting large motors from weak power supply
      (diesel generators, long supply lines, etc.)

Marine & Offshore Applications

    • Thrusters
    • Cargo Pumps (LNG, LPG, etc.)
    • Water & Ballast pumps
    • Refrigeration compressors
    • Hydraulic pumps & power packs
    • Main Propulsion (Variable Pitch Propellers)
 
 
Virtual Web Designs - Telephone 01493 701796